Fire Ratings of 30, 60, 90 and 120 Minutes: What They Mean and How to Choose

When a door schedule says "60-minute fire-rated door", the number is not an approximation. It is the time this door, with its frame and hardware, withstood an approved fire test. This article explains what the 30, 60, 90 and 120 minute ratings mean, who sets them and what changes in the door with each rating.

What does the fire rating mean?

The fire rating is the time for which the door prevents the passage of flame when tested in a furnace along a standard temperature curve. The test is carried out on the door as a complete assembly: leaf, frame, hinges, lock and intumescent strips. So the leaf cannot be judged alone, and changing any component may void the rating.

Ratings available in each system

SystemRatingFire resistance
British (BS)FD3030 minutes
FD6060 minutes
FD9090 minutes
FD120120 minutes
UL (wooden doors)20 minutes20 minutes
45 minutes45 minutes
60 minutes60 minutes
90 minutes90 minutes

In the British system the rating is written as FD followed by the number of minutes. In the UL system the number of minutes is stated directly, and the highest rating for wooden doors is 90 minutes.

Who sets the required rating for each door?

The rating is not chosen by the manufacturer or the contractor. It is set by the project consultant according to the building code and Civil Defense requirements, and written in the door schedule and fire protection drawings. As a general rule, the door rating follows the rating of the wall it is installed in and its position on the escape routes.

Common examples only; they do not replace the project drawings:

  • Room doors opening onto corridors are often specified with short ratings (20 or 30 minutes).
  • Serviced apartment doors and compartment separations are often specified at 60 minutes.
  • Doors to stairs, service rooms and shafts are often specified at 90 minutes or more.

What changes in the door as the rating increases?

  • In the British system (BS): leaf thickness increases with the rating. Typically 44 mm for FD30 and 54 mm for FD60, and more beyond that.
  • In the UL system: a mineral core is used, so thickness stays close to a standard door even at 90 minutes, and the weight is lower.
  • Hardware: hinges, locks and the door closer must be compatible with the rating of the door itself.
  • Glazing: the permitted vision panel area and glass type change with the rating.

How do you make sure the door really achieves the rating?

  • Ask for the manufacturer's certificate from an independent certification body, and verify it directly in that body's directory.
  • Check that the required rating and system (BS or UL) fall within the scope of the certificate.
  • Inspect the certification label on the door at delivery.
  • Make sure installation follows the system instructions; incorrect installation voids the door's rating.

What we manufacture

Fire-rated doors from MEZ are manufactured at Afkar Mumayaza factory, a branch of Mez United Industry Co., certified by IFC Certification: to British Standard from FD30 to FD120 (certificate IFCC1800), and to UL from 20 to 90 minutes (certificate IFCC 1998). Details are on our fire-rated doors page, and the comparison of the two systems is in our article BS vs UL fire-rated doors.